DRT2

Contact sales

+90 216 540 59 91

Request a Price Quote

Description

DRT2

Smart DeviceNet I/O

Compact DeviceNet I/O units with extensive diagnostic functions. Data regarding power supply status, I/O response times, operation counters and on-time are continuously recorded and checked against user-defined limits. Any deviation is reported to the control system, as indication to perform machine maintenance and prevent unplanned downtime. Smart DeviceNet I/Os are supported by PLC Function Blocks and HMI Smart Active Parts, allowing program-less visualisation and monitoring from the CJ1 PLCs and NS operator terminals.

  • Compact size IP20 housing
  • Expandable digital I/Os
  • Built-in diagnostics and preventive maintenance functions
  • Detachable I/O terminal blocks
  • Analog I/O with data pre-processing and alarm functions

Features

Smart features

All Omron I/O units have built-in Smart Features that help to:

  • Reduce engineering time
  • Plan preventative maintainance
  • Increase your productivity

Take a look at one of the features below for a demonstration.

Calendar

Smart I/O can store the last date on which you performed maintenance. A better overview will help you plan maintenance more efficiently.

Counter

Smart I/O units all keep track of duration and number of operations, to help you plan machine maintenance. Timely warnings to inspect and adjust the machine will minimise unplanned downtime.

Volt meter

Smart I/O monitors its own supply voltage, and will warn you if the voltage is out of safe range – e.g. due to damaged cable or poor connection.

Stopwatch

Smart I/O can measure delays between two I/O signals with millisecond accuracy. When your preset limit is exceeded, Smart I/O will warn you that wear or lack of lubrication has reduced machine performance.

Calculator

Smart Analog I/O performs data pre-processing to help you reduce PLC programming. Scaling and alarms, and even totalising or rate-of-change calculations are handled inside the unit.

Specifications & ordering info

Ordering information

Unit type

Specifications

Size in mm (H×W×D)

Remarks

Order code

8-point PNP input unit

24 VDC, 6 mA per point

50×115×50

DRT2-ID08-1

16-point PNP input unit

24 VDC, 6 mA per point

50×115×50

Expandable with one XWT unit

DRT2-ID16-1

16-point PNP input unit

24 VDC, 6 mA per point

50×180×58

3-tier connection for direct sensor wiring

DRT2-ID16TA-1

8-point PNP output unit

24 VDC, 0.5 A per point

50×115×50

DRT2-OD08-1

16-point PNP output unit

24 VDC, 0.5 A per point

50×115×50

Expandable with one XWT unit

DRT2-OD16-1

16-point PNP output unit

24 VDC, 0.5 A per point

50×180×58

3-tier connection for direct actuator wiring

DRT2-OD16TA-1

16-point relay output unit

2 A per point, max. 8 A per common

50×125×52

with easy-to-replace relays, expandable with one XWT unit

DRT2-ROS16

8-point input + 8-point output unit (PNP)

24 VDC, input 6 mA, output 0.5 A per point

50×115×50

DRT2-MD16-1

8-point input + 8-point output unit (PNP)

24 VDC, input 6 mA, output 0.5 A per point

50×180×58

3-tier connection for direct sensor/actuator wiring

DRT2-MD16TA-1

4-Channel analog input unit

0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA

50×115×50

Resolution 1/6000, conversion time 4 ms (4 inputs)

DRT2-AD04

4-Channel analog input unit

1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA

50×115×50

Resolution 1/30000, conversion time 250 ms (4 inputs)

DRT2-AD04H

2-Channel analog output unit

0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA

50×115×50

Resolution 1/6000, conversion time 2 ms (2 outputs)

DRT2-DA02

4-Channel temperature input unit

Platinum Resistance Thermometer types Pt100, JPt100

50×115×50

0.3% accuracy, conversion time 250 ms (4 inputs)

DRT2-TS04P

4-Channel temperature input unit

Thermocouple types R, S, K, J, T, B, L, E, U, N, W,
and PL2

50×115×50

0.3% accuracy, conversion time 250 ms (4 inputs)

DRT2-TS04T

Expansion units

Unit type

Specifications

Size in mm (H×W×D)

Remarks

Order code

8-point PNP input expansion unit

24 VDC, 6 mA per point

50×66×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-ID08-1

16-point PNP input expansion unit

24 VDC, 6 mA per point

50×94×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-ID16-1

8-point PNP output expansion unit

24 VDC, 0.5 A per point

50×66×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-OD08-1

16-point PNP output expansion unit

24 VDC, 0.5 A per point

50×94×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-OD16-1

Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the “-1” from the model code.

Accessories

Type

Order code

Power supply tap with 2 fuses, 2 bus connectors and termination resistor

DCN1-1P

T-branch tap with 3 bus connectors (screw clamp) and terminating resistor

DCN1-1C

T-branch tap with 3 bus connectors (screwless)

DCN1-1NC

T-branch tap with 5 bus connectors (screw clamp) and terminating resistor

DCN1-3C

T-branch tap with 5 bus connectors (screwless)

DCN1-3NC

Terminating resistor with screw terminals

DRS1-T

Downloads

Brochures


Catalogue


Device description files


Manuals


Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[…]CM-B

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[…]CM-Y

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[…]CM-G

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[…]CM-G

Note: For […] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

Note: For [.] fill in the 1-character length code.

Specifications

Item

XS6W-6LSZH8SS_CM-_

XS6W-5PUR8SS_CM-G

Rated current

1 A (at 50°C)

Withstand voltage

1,000 VDC for 60 s (leakage current: 1 mA max.)

Ambient operating temperature

−20 to 60°C

−40 to 85°C

Ambient storage temperature

−20 to 60°C

−40 to 85°C

Ambient installation temperature

0 to 50°C

−10 to 60°C

Protective structure

IP20

IP20

Accessories

Ethernet cables and accessories

Accessories

Type

Connector

Specification

Color

Length

Order code

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 24/1
(solid core), Polyurethane (PUR)

Green

100 m

WM IE-5IC4x2xAWG24/1-PUR

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 26/7
(stranded core), Polyurethane (PUR)

100 m

WM IE-5CC4x2xAWG26/7-PUR

Ethernet socket

RJ45 socket

DIN-rail mount socket to terminate
installation cable in the cabinet

Grey

60 × 17.5 × 67 mm

WM IE-TO-RJ45-FJ-B

Ethernet field-mount plugs

Metal RJ45

for AWG22 to AWG26

Chrome

52 mm

WM IE-PS-RJ45-FH-BK

Ethernet field-mount plugs

Plastic RJ45

for AWG22 to AWG24

Black

52 mm

XS6G-T421-1

Industrial switching hubs

Shape

Functions

Ports

Failure detection

Power supply voltage

Order code

Quality of Service (QoS):

EtherNet/IP control data priority

Failure detection:

Broadcast storm and LSI error detection
10/100BASE-TX, Auto-negotiation

3

24.0 VDC±5%

W4S1-03B

5

W4S1-05B

W4S1-05C

EtherCAT junction slave

Shape

Functions

Ports

Power supply voltage

Order code

Creation of star- and tree topologies
in EtherCAT networks.

Distributed Clock (DC) is supported.

3

20.4 to 28.8 VDC

(24 VDC –15% to 20%)

GX-JC03

6

GX-JC06