From single machine to production line all, safety interconnect
Quick, easy, and flexible to integrate safety into production lines combining two different integrated networks, EtherNet/IP (Common Industrial Protocol Safety (CIP-S)) and EtherCAT (Safety over EtherCAT (FSoE))
1 built-in EnerNet/IP port (100Base-TX)
1 built-in CIP-Safety on EtherNet/IP port (max 16 communication CIP-Safety)
1 built-in FSoE on EtherCAT master port (max 64 nodes)
Up to 254 safety connections with NX-SL5700
Up to 32 local NX I/O units
Multi-cast packet possible
Up to 12 axes (8 synchronized motion axes & 4 PTP)
2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C
The maximum load current depends on the installation orientation and ambient temperature.
24 VDC
1
Free-Run refreshing
Ver. 1.0
NX-SOH200
4 points
0.5 A/point and 2.0 A/Unit
NX-SOD400
NX-series Standard I/O units
For the selection of standard I/O units please refer to the NX Series product website (https://industrial.omron.eu/en/products/nx-series).
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.
Sysmac Studio runs on the following OS.
Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version)
– (Media only)
DVD
SYSMAC-SE200D
Note:For details of the Automation Software Sysmac Studio, refer to your local OMRON website.
Optional Products
Product name
Specifications
Order code
Memory Card
SD memory card, 2 GB
HMC-SD291
SD memory card, 4 GB
HMC-SD491
Unit/Terminal Block Coding Pins
For 10 Units (Terminal Block: 30 pins, Unit: 30 pins)
NX-AUX02
Product name
Specifications
Order code
No. of terminals
Terminal number indications
Ground terminal mark
Terminal current capacity
Terminal Block
8
A/B
Provided
10 A
NX-TBC082
8
A/B
None
10 A
NX-TBA082
16
A/B
None
10 A
NX-TBA162
Accessories
Communication Control Unit Accessories
Product name
Remark
Order code
End Cover
One End Cover is provided with the Communication Control Unit.
NRAQ (UL61010-1, and UL 61010-2-201)NRAG (ANSI/ISA 12.12.01, or UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)FSPC (IEC 61508 and ISO 13849)
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
– Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC/EN 62061, (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
– Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1The NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.
General Specifications
Item
Specifications
Enclosure
Mounted in a panel (open)
Grounding method
Ground to 100 Ω or less
Operating
environment
Ambient operating temperature
0 to 55°C
Ambient operating humidity
10% to 95% (with no condensation or icing)
Atmosphere
Must be free from corrosive gases.
Ambient storage temperature
−25 to 70°C (with no condensation or icing)
Altitude
2,000 m max.
Pollution degree
2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise immunity
Conforms to IEC 61131-2.
2 kV on power supply line
Insulation class
Class III (SELV)
Overvoltage category
Category II: Conforms to JIS B3502 and IEC 61131-2.
EMC immunity level
Zone B
Vibration resistance
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude
8.4 to 150 Hz, acceleration of 9.8 m/s2
100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Shock resistance
Conforms to IEC 60068-2-27.
147 m/s2, 3 times each in X, Y, and Z directions
Connected to a Communications Coupler Unit
6 possible orientations.
Restrictions:
For upright installation, the ambient temperature is restricted as shown below depending on the total Unit load current.For all installation orientations other than upright installation, the ambient temperature is restricted as shown below according to the total Unit load current.
Installation orientation:
Connected to a CPU Unit or a Communication Control Unit
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Recent Comments