NX I/O Series

Contact sales

+90 216 540 59 91

Request a Price Quote

 

 

Description

NX I/O Series

Performance and practicality for machine control

Modern machine control requires system-wide synchronisation of motion axes with microsecond accuracy. The NX I/O system offers this timing accuracy and repeatability for a wide variety of in- and outputs. Its ultra-fast internal bus system is synchronised with the Distributed Clock of the EtherCAT network, resulting in system-wide deterministic I/O operation.

  • Ideal match with Sysmac Machine automation controllers and CJ2-series PLC’s
  • Synchronous I/O updates, system-wide, with less than 1 μs jitter using EtherCAT
  • High density: up to 16 digital or 8 analog signals in 12 mm width
  • Removable wiring terminals for easy system assembly and testing

Features

Networks

ethercat-net-profinet 190x206px prod

We chose EtherCAT as control network for the Sysmac NJ Machine Controller series. The convenience of standard Ethernet cabling combined with extremely fast on-the-fly data exchange have resulted in a new machine control architecture. The resulting openness, modularity and determinism are the key elements in today’s machine automation.

  • Using open standards for programming and networking assure exchangeability and interoperability with external systems
  • Modularity allows flexibility in system configurations for fast adaptation to end-user requirements
  • Determinism is needed to keep control of the machine while increasing performance and accuracy

EtherNet/IP uses the CIP protocol over standard Ethernet infrastructure to offer efficient yet reliable data exchange. Using the EtherNet/IP bus coupler, NX-series I/O – including safety control – can be connected to CJ/CS-series PLC’s.

ProfiNet bus coupler expands NX I/O platform capabilities enabling a wider range of possible architectures.

 

Performance

synchronous io prod

Since each set of NX-series I/O’s on an EtherCAT coupler counts as just a single EtherCAT node, the overall network performance is hardly affected by the number of installed I/O units. Keeping the number of EtherCAT nodes to a minimum will help to keep the refresh cycle times of EtherCAT motion axes as low as possible, even at high I/O counts. Furthermore, local fault or damage to an I/O unit will not affect other EtherCAT nodes down the line. The internal bus of the NX-series is fully synchronised with the EtherCAT Distributed Clock. This assures exact timing of any in- or output unit in the control system to within 1 µs, wherever the I/O units are mounted.

Design

push-in wiring prod

 

For the design of the NX-series, we used our experience in distributed I/O systems combined with customer feedback.

  • The units are compact, with a standard width of 12 mm per unit, yet offer up to 16 channels per unit
  • The front connectors feature toolless push-in wiring with 8 mm ferrules for wire up to 1.5 mm2
  • The terminals are removable to allow pre-wiring and safe step-by-step testing
  • Matching labels on unit and connector reduce the chance of incorrect assembly
  • You can insert 6 keys in the terminal and the unit to mechanically prevent a mismatch

 

Digital I/O Units

nx digital io prod

The NX-series let you mix economical standard I/O’s with high-speed synchronous models. The standard digital I/O’s have 16 connections per unit, with a choice of:

  • 3-wire sensor connection with power supply (4-channel units)
  • 2-wire contact inputs or actuator outputs (8-channel-units)
  • 1-wire connection for sensors and actuators already connected to a common power supply (16-channel units)

 

High-speed I/O’s all use 3-wire connection, and have On/Off response times of less than 300 ns. Using the EtherCAT Distributed Clock, all inputs can be latched, and outputs can be controlled synchronously, with less than 1 µs jitter.

For even more control over the exact I/O timing, time-stamp inputs will tell you the exact time of each signal transition. Similarly, time-stamp outputs anywhere in the EtherCAT network can be independently controlled with sub-microsecond accuracy.

Analog I/O Units

nx analogue i o units prod

Input signals from analog sensors, 4-20 mA transmitters, thermocouples or resistance thermometers can easily be connected and used for monitoring, data logging, trending or PID control. Analog units are offered with sampling times down to 10 µs per channel and high resolution (1:30,000). Built-in filtering, offset correction, broken wire- and overrange detection are all standard functions. The user can select from 12 different thermocouple characteristics, °C/°F and indication resolution down to 0.01 degree. With up to eight inputs in just 12 mm width, the NX-series are among the most compact modules on the market today.

High-speed analog input unit

nx-had401 190x232 prod

The High-speed Analog Input Unit allows an up to 5µs sampling rate on analog signals. The fast measuring of analog signals enables an improved quality inspection or a vibration analysis for predictive maintenance. Machine’s Quality and Availability can be improved resulting then in a better OEE (Overall Equipment Effectiveness) rate. This unit can read up to 4 different signals at the same time by keeping the 5µs even if the 4 channels are used. The isolation between channels prevents from distortion between channels.

Position I/O Units

nx position i o units prod

Various types of encoder signals can be connected, from incremental to Synchronous Serial (SSI) encoders. The ability to synchronize the position data with the EtherCAT Distributed Clock means that the encoder can be used as a motion axis for gearing or following. Pulse outputs up to 500 kHz can be used for discrete control or positioning and can also be mapped as a motion axes when used with the Sysmac NJ machine controller.

IO-Link Master Unit

nxilm400 prod

IO-Link makes communication down to the sensor level visible

  • Machine downtime can be reduced.
  • Abnormality detection for shortest recovery.
  • Condition monitoring for predictive maintenance.
  • Individual identification for reduction of man hours.
  • NX I/O Series Master unit with screw-less terminal block or GX Series with IP67 protection class for watery and dusty environments.
  • Up to 4 sensors can be connected with one NX I/O Series IO-Link master unit.
  • Photoelectric and Proximity sensors available.

 

Integrated Safety

nx safety prod

 

Safety control units and safe in- and output units can be added to any NX-series EtherCAT I/O stations, to fully integrate safety and standard control in one network. The NX-series fulfills all safety Performance Levels from PL a to PL e. Since the standard NJ-series controllers (V1.06 and up) and NX-series bus couplers (V1.1 and up) can be used, standard control and safety can be scaled independently.

More information

 

Temperature Control

nx in-panel tc prod

 

Optimize Control by Detecting Status Changes Easily Satisfy Both Productivity and Quality

  • Adaptive control for self-optimization of control setting due to process changes
  • Specialized function for better sealing application (packaging) and for water-cooled extruders (plastic)
  • Easier integration thanks to ProfiNet, Ethernet-IP and EtherCAT Fieldbus support

More information

Specifications & ordering info

Ordering information

Communication and control units

Module Type

Protocol

Connection

Specification

Width

Order code

Communication coupler

EtherCAT Slave

2 RJ45 ports

(in + out)

Up to 63 I/O units.

Max. 1,024 bytes in + 1,024 bytes out

Supports distributed clock

I/O power supply up to 10 A

46 mm

NX-ECC203

EtherNet/IP Slave

2 RJ45 ports

with built-in switch

Up to 63 I/O units.

Max. 512 bytes in + 512 bytes out

Supports local safety communication

Free Run I/O refresh mode only

I/O power supply up to 10 A

NX-EIC202

Safety controller

FSoE Protocol

128 Safety connections

For up to 1,024 safety I/O points

30 mm

NX-SL3500

32 Safety connections

For up to 256 safety I/O points

NX-SL3300

IO-Link master unit

Module Type

No. of ports

I/O refresh method

Connection type

Width

Order code

IO-Link master

4

Free Run

Screwless push-in (NX-TBA162)

12 mm

NX-ILM400

Note: For more detailed information about IO-Link master unit, refer to “IO-Link master datasheet (I191E-EN)”.

Digital I/O units

Module type

Channels, Signal type

Performance

, I/O Refresh Mode

Connection type

Width

Order code

NPN-type

AC Digital Input

4 inputs, 200 to 240 VAC, 50/60 Hz

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-IA3117

Safety Digital Input

4 inputs + 2 test outputs

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SIH400

8 inputs + 2 test outputs

Screwless push-in (NX-TBA162)

NX-SID800

DC Digital Input

4 inputs, 3-wire connection

High-speed Synchronous Time Stamp

Screwless push-in (NX-TBA122)

12 mm

NX-ID3444

NX-ID3344

High-speed Synchronous/Free Run

NX-ID3443

NX-ID3343

Synchronous/Free Run

NX-ID3417

NX-ID3317

8 inputs, 2-wire connection

Screwless push-in (NX-TBA162)

NX-ID4442

NX-ID4342

16 inputs, 1-wire connection

NX-ID5442

NX-ID5342

1 × 20-pin MIL connector

30 mm

NX-ID5142-5

same

M3 screw

NX-ID5142-1

same

32 inputs, 1-wire connection

1 × 40-pin MIL connector

NX-ID6142-5

same

1 × 40-pin Fujitsu connector

NX-ID6142-6

same

DC Digital I/O

16 inputs + 16 outputs 0.5 A,
1-wire connection + common

Synchronous/Free Run

2 × 20-pin MIL connector

30 mm

NX-MD6256-5

NX-MD6121-5

2 × 24-pin Fujitsu connector

NX-MD6121-6

DC Digital Output

2 outputs 0.5 A, 3-wire connection

High-speed Synchronous Time Stamp

Screwless push-in (NX-TBA082)

12 mm

NX-OD2258

NX-OD2154

4 outputs 0.5 A, 3-wire connection

High-speed Synchronous/Free Run

Screwless push-in (NX-TBA122)

NX-OD3257

NX-OD3153

Synchronous/Free Run

NX-OD3256

NX-OD3121

4 outputs 2 A/point, 8 A total, 3-wire connection

Screwless push-in (NX-TBA162)

NX-OD3268

8 outputs 0.5 A, 2-wire connection

NX-OD4256

NX-OD4121

16 outputs 0.5 A, 1-wire connection

NX-OD5256

NX-OD5121

1 × 20-pin MIL connector

30 mm

NX-OD5256-5

NX-OD5121-5

M3 screw

NX-OD5256-1

NX-OD5121-1

32 outputs 0.5 A, 1-wire connection

1 × 40-pin MIL connector

NX-OD6256-5

NX-OD6121-5

1 × 40-pin Fujitsu connector

NX-OD6121-6

Safety Digital Output

2 outputs, 2.0 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SOH200

4 outputs, 0.5 A

NX-SOD400

Relay Digital Output

2 outputs, N.O., 2.0 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-OC2633

8 outputs, N.O., 2.0 A

24 mm

NX-OC4633

2 outputs, N.O.+ N.C., 2.0 A

12 mm

NX-OC2733

Analog I/O units

Module type

Signal type

Performance, I/O Refresh Mode

Channels

Connection type

Width

Order code

Temperature Sensor Input

Thermocouple type
B,E,J,K,L,N,R,S,T,U,WRe5-26,PLII

0.1°C resolution, 200 ms/unit
Free Run

2

Screwless push-in terminal block(s) with cold junction sensor, calibrated individually at the factory

12 mm

NX-TS2101

4

24 mm

NX-TS3101

0.01°C resolution, 10 ms/unit
Free Run

2

12 mm

NX-TS2102

4

24 mm

NX-TS3102

0.001°C resolution, 60 ms/unit
Free Run

2

12 mm

NX-TS2104

4

24 mm

NX-TS3104

RTD type
Pt100 (3-wire), Pt1000, Ni508.4

0.1°C resolution, 200 ms/unit
Free Run

2

Screwless push-in (NX-TBA162)

12 mm

NX-TS2201

4

Screwless push-in
(NX-TBA162 + NX-TBB162)

24 mm

NX-TS3201

0.01°C resolution, 10 ms/unit
Free Run

2

Screwless push-in (NX-TBA162)

12 mm

NX-TS2202

4

Screwless push-in
(NX-TBA162 + NX-TBB162)

24 mm

NX-TS3202

0.001°C resolution, 60 ms/unit
Free Run

2

Screwless push-in (NX-TBA162)

12 mm

NX-TS2204

4

Screwless push-in
(NX-TBA162 + NX-TBB162)

24 mm

NX-TS3204

Analog Input

4 to 20 mA
single ended

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

12 mm

NX-AD2203

4

Screwless push-in (NX-TBA122)

NX-AD3203

8

Screwless push-in (NX-TBA162)

NX-AD4203

4 to 20 mA
differential

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

NX-AD2204

4

Screwless push-in (NX-TBA122)

NX-AD3204

8

Screwless push-in (NX-TBA162)

NX-AD4204

1/30000 resolution,10 µs/channel
Synchronous/Free Run

2

Screwless push-in (NX-TBA082)

NX-AD2208

4

Screwless push-in (NX-TBA122)

NX-AD3208

8

Screwless push-in (NX-TBA162)

NX-AD4208

−10 to 10 V
single ended

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

NX-AD2603

4

Screwless push-in (NX-TBA122)

NX-AD3603

8

Screwless push-in (NX-TBA162)

NX-AD4603

−10 to 10 V
differential

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

NX-AD2604

4

Screwless push-in (NX-TBA122)

NX-AD3604

8

Screwless push-in (NX-TBA162)

NX-AD4604

1/30000 resolution,10 µs/channel
Synchronous/Free Run

2

Screwless push-in (NX-TBA082)

NX-AD2608

4

Screwless push-in (NX-TBA122)

NX-AD3608

8

Screwless push-in (NX-TBA162)

NX-AD4608

High-Speed Analog Input

−10 to 10 V, −5 to 5 V, 0 to 10 V,
0 to 5 V, 1 to 5 V, 0 to 20 mA,
4 to 20 mA
differential

−10 to 10 V or −5 to 5 V: 1/64000
Other input range: 1/32000
5 µs/channel
Synchronous

4 (NPN)

Screwless push-in
(NX-TBA162 + NX-TBB162)

24 mm

NX-HAD401

4 (PNP)

NX-HAD402

Analog Output

4 to 20 mA

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

12 mm

NX-DA2203

4

Screwless push-in (NX-TBA122)

NX-DA3203

1/30000 resolution,10 µs/channel
Synchronous/Free Run

2

Screwless push-in (NX-TBA082)

NX-DA2205

4

Screwless push-in (NX-TBA122)

NX-DA3205

−10 to 10 V

1/8000 resolution, 250 µs/channel
Free Run

2

Screwless push-in (NX-TBA082)

NX-DA2603

4

Screwless push-in (NX-TBA122)

NX-DA3603

1/30000 resolution,10 µs/channel
Synchronous/Free Run

2

Screwless push-in (NX-TBA082)

NX-DA2605

4

Screwless push-in (NX-TBA122)

NX-DA3605

Temperature control units

Module type

Conversion time,
I/O Refresh Mode

Channels

Input type

Output type

Output capacity

CT Input capacity

Control type

Connection type

Width

Order code

Temperature control

50 ms
Free run

2

Multi-input

(Thermo-
couple and Resistance

thermometer)

Voltage output

(for driving SSR)

2 points

2 points

Standard

Screwless push-in (NX-TBA162)

12 mm

NX-TC2405

NX-TC2406

4 points

Heating and Cooling

NX-TC2407

Linear current output

2 points

Standard

NX-TC2408

4

Voltage output

(for driving SSR)

4 points

4 points

Standard

Screwless push-in
(NX-TBA162 + NX-TBB162)

24 mm

NX-TC3405

NX-TC3406

8 points

Heating and Cooling

NX-TC3407

Linear current output

4 points

Standard

NX-TC3408

Heater burnout detection units

Module type

Channels, signal type

Control output

I/O refresh method

Connection type

Width

Order code

Heater burnout detection

4 CT inputs
4 control outputs

NPN, 12 to 24 VDC
0.1 A/point, 0.4 A/unit

Free Run

Screwless push-in (NX-TBA162)

12 mm

NX-HB3101

PNP 24 VDC
0.1 A/point, 0.4 A/unit

NX-HB3201

Load cell input unit

Module type

Specifications

Excitation voltage/input range

I/O refresh method

Connection type

Width

Order code

Load cell input

1 load cell input, 125 µs conversion cycle

5 VDC ±10%/−5 to 5 mV/V

Synchronous/Free Run

Screwless push-in (NX-TBC162)

12 mm

NX-RS1201

Position control units

Module type

Channels, Signal type

Performance, I/O Refresh Mode

Connection type

Width

Order code

NPN-type

Encoder Input

1 SSI encoder, 2 MHz

Synchronous/Free Run

Screwless push-in (NX-TBA122)

12 mm

NX-ECS112

2 SSI encoders, 2 MHz

NX-ECS212

1 incremental encoder line driver 4 MHz + 3 Digital Inputs (1 µs)

Screwless push-in
(NX-TBA122 + NX-TBB122)

24 mm

NX-EC0142

NX-EC0132

1 incremental encoder open collector 500 kHz + 3 Digital Inputs (1 µs)

Screwless push-in (NX-TBA162)

12 mm

NX-EC0122

NX-EC0112

2 incremental encoders open collector 500 kHz

Screwless push-in (NX-TBA122)

NX-EC0222

NX-EC0212

Pulse Output

1 Pulse Up/Down or Pulse/Direction open collector 500 kHz + 2 Digital Inputs + 1 Digital Output (1 µs)

Synchronous

Screwless push-in (NX-TBA162)

12 mm

NX-PG0122

NX-PG0112

2 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital outputs per channel

1 × 34-pin MIL connector

30 mm

NX-PG0242-5

NX-PG0232-5

4 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital outputs per channel

2 × 34-pin MIL connector

NX-PG0342-5

NX-PG0332-5

Serial communication interface units

Module type

Channels, Signal type

Performance, I/O Refresh Mode

Connection type

Width

Order code

NPN-type

Serial Communication

1 × RS-422A/485

Free Run

Screwless push-in (NX-TBC162)

12 mm

NX-CIF105

1 × RS-232C

NX-CIF101

2 × RS-232C

9-pin D-sub

30 mm

NX-CIF210

Digital I/O performance

Standard

High Speed

ON delay

OFF delay

ON delay

OFF delay

Input

PNP

0.02 ms

0.4 ms

100 ns

100 ns

NPN

AC

10 ms

40 ms

N.A.

N.A.

Output

PNP

0.5 ms

1.0 ms

300 ns

300 ns

NPN

0.1 ms

0.8 ms

Relay

15 ms

15 ms

N.A.

N.A.

*2 Units with screwless push-in connections are supplied with the appropriate terminal connector. Units with MIL/Fujitsu connectors are supplied without matching plugs; for connecting cables see page

*3 Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP.

Other units

Module type

Description

Connection type

Width

Order code

Power Unit

NX bus power supply unit, 24 V DC input, non-isolated

Screwless push-in (NX-TBC082)

12 mm

NX-PD1000

I/O power feed unit, for separation of power groups, up to 10 A

Screwless push-in (NX-TBA082)

NX-PF0730

I/O power connection unit, 16 × IOV

Screwless push-in (NX-TBA162)

NX-PC0020

I/O power connection unit, 16 × IOG

NX-PC0010

I/O power connection, 8 × IOV + 8 x IOG

NX-PC0030

System Units and Accessories

Grounding terminal, 16 points

Screwless push-in (NX-TBC162)

NX-TBX01

End cover (included with Communication Coupler)

NX-END01

Replacement front connector with 8 wiring terminals (marked A+B)

Screwless push-in

NX-TBA082

Replacement front connector with 12 wiring terminals (marked A+B)

NX-TBA122

Replacement front connector with 16 wiring terminals (marked A+B)

NX-TBA162

Replacement front connector with 12 wiring terminals (marked C+D)

NX-TBB122

Replacement front connector with 16 wiring terminals (marked C+D)

NX-TBB162

Replacement front connector with 8 wiring terminals (marked A+B+FG)

NX-TBC082

Replacement front connector with 16 wiring terminals (marked A+B+FG)

NX-TBC162

DIN rail insulation spacers, set of 3 pcs

NX-AUX01

30 Unit pins + 30 Terminal keying pins, to prevent mismatch of unit and terminal block (one set is enough for 10 units)

NX-AUX02

Accessories

Type

Description

Connection type

Width

Order code

End cover

Included with communication coupler

12 mm

NX-END01

Terminal block (replacement front connector)

With 8 wiring terminals (A + B)

Screwless push-in

NX-TBA082

With 8 wiring terminals (A + B with FG)

NX-TBC082

With 12 wiring terminals (A + B)

NX-TBA122

With 12 wiring terminals (C + D)

NX-TBB122

With 16 wiring terminals (A + B)

NX-TBA162

With 16 wiring terminals (C + D)

NX-TBB162

With 16 wiring terminals (A + B with FG)

NX-TBC162

DIN rail insulation spacers

Set of 3 pcs

NX-AUX01

Terminal block coding pins

For 10 units (Terminal block: 30 pins, unit: 30 pins)

NX-AUX02

End plate

To secure the units on the DIN track

PFP-M

Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[…]CM-B

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[…]CM-Y

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[…]CM-G

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[…]CM-G

Note: For […] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

Note: For [.] fill in the 1-character length code.

Specifications

Item

XS6W-6LSZH8SS_CM-_

XS6W-5PUR8SS_CM-G

Rated current

1 A (at 50°C)

Withstand voltage

1,000 VDC for 60 s (leakage current: 1 mA max.)

Ambient operating temperature

−20 to 60°C

−40 to 85°C

Ambient storage temperature

−20 to 60°C

−40 to 85°C

Ambient installation temperature

0 to 50°C

−10 to 60°C

Protective structure

IP20

IP20

Accessories

Ethernet cables and accessories

Accessories

Type

Connector

Specification

Color

Length

Order code

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 24/1
(solid core), Polyurethane (PUR)

Green

100 m

WM IE-5IC4x2xAWG24/1-PUR

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 26/7
(stranded core), Polyurethane (PUR)

100 m

WM IE-5CC4x2xAWG26/7-PUR

Ethernet socket

RJ45 socket

DIN-rail mount socket to terminate
installation cable in the cabinet

Grey

60 × 17.5 × 67 mm

WM IE-TO-RJ45-FJ-B

Ethernet field-mount plugs

Metal RJ45

for AWG22 to AWG26

Chrome

52 mm

WM IE-PS-RJ45-FH-BK

Ethernet field-mount plugs

Plastic RJ45

for AWG22 to AWG24

Black

52 mm

XS6G-T421-1

Industrial switching hubs

Shape

Functions

Ports

Failure detection

Power supply voltage

Order code

Quality of Service (QoS):

EtherNet/IP control data priority

Failure detection:

Broadcast storm and LSI error detection
10/100BASE-TX, Auto-negotiation

3

24.0 VDC±5%

W4S1-03B

5

W4S1-05B

W4S1-05C

EtherCAT junction slave

Shape

Functions

Ports

Power supply voltage

Order code

Creation of star- and tree topologies
in EtherCAT networks.

Distributed Clock (DC) is supported.

3

20.4 to 28.8 VDC

(24 VDC –15% to 20%)

GX-JC03

6

GX-JC06

Downloads

Brochures


Catalogue


Connection guides


Device description files


Datasheet


Manuals