Description
G9SX
G9SX safety controller – Scalable hardwired solution
G9SX safety controllers are supplied fully configured and pre-programmed, with a wide choice of units designed to be fit for purpose, with no unnecessary functionality. Ideal for use where the flexibility of a programmable safety controller is not needed. The line-up is completed by expansion units with safe timing functions. G9SX units are simple to fit and very robust, with non-wearing solid state outputs. They can be easily connected on modular equipment, and are ideal for non-contact applications where a high number of output cycles is needed.
- Facilitates partial or complete control system setup
- Clear LED diagnosis of all in- and output signals for easy maintenance
- Easy integration
- Solid-state outputs (excluding Expansion Units)
- Approved by UL and CSA and EN ISO 13849-1 certified
Models
G9SX-AD/-BC/-EX – Flexible safety unit
- Clear and transparent segmentation of safety functions by use of unique “AND” connection
- Solid-state outputs for long life and relay outputs in extension box available
- Detailed LED indications enable easy diagnosis
- Clever feedback signals for easy maintenance
- Up to PLe/Cat.4 according to EN ISO 13849-1 and SIL 3 according to IEC 61508
G9SX-GS Safety guard switching unit
- Two operation modes to support: 1) Auto switching for applications where machine and worker co-operate. 2) Manual switching for applications with limitation in operation like maintenance.
- Clear and transparent segmentation of safety functions by use of unique “AND”connection
- Clear LED diagnosis of all in- and output signals for easy maintenance
- Up to PLe/Cat.4 according to EN ISO 13849-1 and SIL 3 according to IEC 61508
G9SX-SM – Standstill monitoring unit
- Ready to use – covering all standard applications without additional setup
- Easy integration in star- and delta wiring
- Clear LED diagnosis of all in- and output signals for easy maintenance
- Up to PLe/Cat.4 according to EN ISO 13849-1
G9SX-LM – Limited speed monitoring unit
- Preset of limited speed frequency by using integrated preset switches
- Easy integration in G9SX-Systems by using unique logical “AND” connection
- Clear LED diagnosis of all in- and output signals for easy maintenance
- Up to PLd/Cat.3 according to EN ISO 13849-1
G9SX-NS – Electronic non-contact door monitoring system
- Stable operation reduce controller errors caused by unstable doors
- Connect up to 30 non-contact door switches with LED to one controller
- Clear LED diagnosis of all in- and outputs
- Up to PLd/Cat.3 according to EN ISO 13849-1
Specifications & ordering info
Specifications & ordering info
Ordering information
Advanced unit
|
Safety outputs
|
Auxiliary outputs
|
No. of input
channels
|
Max. OFF-delay time
|
Rated voltage
|
Terminal block type
|
Order code
|
|
Instantaneous
|
OFF-delayed
|
|
3 P channel MOS-FET transistor output
|
2 P channel MOS-FET transistor output
|
2 PNP transistor
outputs
|
1 or 2 channels
|
0 to 15 sec in
16 steps
|
24 VDC
|
Screw terminals
|
G9SX-AD322-T15-RT
|
|
Cage clamp terminals
|
G9SX-AD322-T15-RC
|
|
2 P channel MOS-FET transistor output
|
2 P channel MOS-FET transistor output
|
2 PNP transistor
outputs
|
1 or 2 channels
|
0 to 150 sec in
16 steps
|
24 VDC
|
Screw terminals
|
G9SX-AD-322-T150-RT
|
|
Cage clamp terminals
|
G9SX-AD-322-T150-RC
|
|
0 to 15 sec in
16 steps
|
24 VDC
|
Screw terminals
|
G9SX-ADA-222-T15-RT
|
|
Cage clamp terminals
|
G9SX-ADA-222-T15-RC
|
|
0 to 150 sec in
16 steps
|
24 VDC
|
Screw terminals
|
G9SX-ADA-222-T150-RT
|
|
Cage clamp terminals
|
G9SX-ADA-222-T150-RC
|
Basic unit
|
Safety outputs
|
Auxiliary outputs
|
No. of input
channels
|
Rated voltage
|
Terminal block type
|
Order code
|
|
Instantaneous
|
OFF-delayed
|
|
2 P channel MOS FET transistor output
|
–
|
2 PNP transistor
output
|
1 or 2 channels
|
24 VDC
|
Screw terminals
|
G9SX-BC202-RT
|
|
Cage clamp terminals
|
G9SX-BC202-RC
|
Expansion unit
|
Safety outputs
|
Auxiliary outputs
|
OFF-delay time
|
Rated voltage
|
Terminal block type
|
Order code
|
|
Instantaneous
|
OFF-delayed
|
|
4 PST-NO (contact)
|
–
|
2 (solid state) PNP
transistor outputs
|
–
|
24 VDC
|
Screw terminals
|
G9SX-EX401-RT
|
|
Cage clamp terminals
|
G9SX-EX401-RC
|
|
–
|
4 PST-NO (contact)
|
Synchronized with
G9S-X-AD – unit
|
Screw terminals
|
G9SX-EX041-T-RT
|
|
Cage clamp terminals
|
G9SX-EX041-T-RC
|
Specifications
Power input
|
Item
|
G9SX-AD_
|
G9SX-BC202-_
|
G9SX-EX-_
|
|
Rated supply voltage
|
20.4 to 26.4 VDC (24 VDC -15% +10%)
|
Inputs
|
Item
|
G9SX-AD_
|
G9SX-BC202-_
|
|
Safety input
|
Operating voltage: 20.4 VDC to 26.4 VDC,
internal impedance: Approx. 2.8 kΩ
|
|
Feedback/reset input
|
Outputs
|
Item
|
G9SX-AD_
|
G9SX-BC202-_
|
|
Instantaneous safety output
OFF-delayed safety output
|
P channel MOS FET transistor output
Load current: Using 2 outputs or less: 1 A DC max.
Using 3 outputs or more: 0.8 A DC max.
|
P channel MOS FET transistor output
Load current: Using 1 output: 1 A DC max.
Using 2 outputs: 0.8 A DC max.
|
|
Auxiliary output
|
PNP transistor output
Load current: 100 mA max.
|
Expansion unit
|
Item
|
G9SX-EX-_
|
|
Rated load
|
250 VAC, 3A/30 VDC, 3A (resistive load)
|
|
Rated carry current
|
3 A
|
|
Maximum switching voltage
|
250 VAC, 125 VDC
|
Characteristics
|
Item
|
G9SX-AD_
|
G9SX-BC202-_
|
G9SX-EX-_
|
|
Operating time (OFF to ON state)
|
50 ms max. (Safety input: ON)
100 ms max. (Logical AND connection input: ON)
|
50 ms max. (Safety input: ON)
|
30 ms max.
|
|
Response time (ON to OFF state)
|
15 ms max.
|
10 ms max.
|
|
Durability
|
Electrical
|
–
|
100,000 cycles min.
|
|
Mechanical
|
–
|
5,000,000 cycles min.
|
|
Ambient temperature
|
-10°C +55°C (with no icing or condensation)
|