G9SA

Contact sales

+90 216 540 59 91

Request a Price Quote

Category:

Description

G9SA

Expandable safety relay unit

G9SA-family offers a complete line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two-hand controller. Simple multiplication of safety contacts is possible by using the connection on the front.

  • 45mm-wide housing, expansion units are 17.5mm wide
  • Safe OFF-delay timer
  • Simple expansion connection
  • Certification up to PLe according to EN ISO 13849-1 depending on the application

 

Datasheet
Click for other safety modules

Specifications & ordering info

Emergency-stop units

Main contacts

Auxiliary contact

Number of input channels

Rated voltage

Order code

3PST-NO

SPST-NC

1 channel or 2 channels possible

24 VAC/VDC

G9SA-301

100 to 240 VAC

5PST-NO

SPST-NC

1 channel or 2 channels possible

24 VAC/VDC

G9SA-501

100 to 240 VAC

Emergency-stop OFF-delay units

Main contacts

OFF-delay contacts

Auxiliary

contact

Number of

input channels

OFF-delay time

Rated voltage

Order code

3PST-NO

DPST-NO

SPST-NC

1 channel or
2 channels
possible

7.5 s

24 VAC/VDC

G9SA-321-T075

100 to 240 VAC

15 s

24 VAC/VDC

G9SA-321-T15

100 to 240 VAC

30 s

24 VAC/VDC

G9SA-321-T30

100 to 240 VAC

Two-hand controller

Main contacts

Auxiliary contact

Number of input channels

Rated voltage

Order code

3PST-NO

SPST-NC

2 channels

24 VAC/VDC

G9SA-TH301

100 to 240 VAC

Expansion unit

The expansion unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.

Main contacts

Auxiliary contact

Category

Order code

3PST-NO

SPST-NC

4

G9SA-EX301

Expansion units with OFF-delay outputs

The expansion unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.

Main contact form

Auxiliary contact

OFF-delay time

Order code

3PST-NO

SPST-NC

7.5 s

G9SA-EX031-T075

15 s

G9SA-EX031-T15

30 s

G9SA-EX031-T30

Specifications

Power input

Item

G9SA-301/TH301 / G9SA-501 / G9SA-321-T_

Power supply voltage

24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC: 100 to 240 VAC, 50/60 Hz

Operating voltage range

85 to 110% of rated power supply voltage

Inputs

Item

G9SA-301/321-T_/TH301

G9SA-501

Input current

40 mA max.

60 mA max.

Contacts

Item

G9SA-301/501/321-T_/TH301/EX301/EX031-T_

Resistive load (cosφ= 1)

Rated load

250 VAC, 5 A

Rated carry current

5 A

Characteristics

Item

G9SA-301/TH301 / G9SA-501/321-T_ / G9SA-EX301/EX031-T_

Operating time

30 ms max. (not including bounce time)

Response time

10 ms max. (not including bounce time)

Durability

Mechanical

5,000,000 operations min. (at approx. 7,200 operations/hr)

Electrical

100,000 operations min. (at approx. 1,800 operations/hr)

Minimum permissible load
(reference value)

5 VDC, 1 mA

Ambient temperature

Operating: -25 to 55°C (with no icing or condensation)
Storage: -25 to 85°C (with no icing or condensation)

Downloads

Catalogue


Datasheet