ZC

Contact sales

+90 216 540 59 91

Request a Price Quote

Description

ZC

Limit switch in compact metal housing with terminal block

The compact housing size and the terminal block with side facing cable exit allow the mounting where space is crucial and self-wiring connection is preferred. The rugged and tight housing construction provides high protection while the low-force actuators make the ZC limit switch ideal for switching smaller or lighter objects.

  • Terminal block for self-wiring with side facing cable exit
  • Low-force actuators for switching smaller or lighter objects
  • Rugged metal housing with IP67 protection

Specifications & ordering info

Ordering Information

Actuator type

Connection method

Order code

Plunger

Terminal block with side facing cable exit (left/right changeable) for cables dia 8.5 to 10.5 mm

ZC-D55

Plunger with M14 mounting

ZC-Q55

Sealed roller plunger

ZC-N2255

Roller plunger with M14 mounting

ZC-Q2255

Sealed cross roller plunger

ZC-N2155

Cross roller plunger with M14 mounting

ZC-Q2155

Hinge lever – 50R

ZC-W55

Hinge lever – 70R

ZC-W155

Hinge roller lever – 50R

ZC-W255

Hinge roller lever – 70R

ZC-W2155

Specifications

Voltage and current rating

Model

Rated voltage

Non-inductive load

Inductive load

Inrush current

Resistive load

Lamp load

Inductive load

Motor load

NC and NO

NC

NO

NC

NO

NC

NO

NC

NO

Standard type

125 VAC

10

3

1.5

10

5

2.5

30 A

15 A

250 VAC

2.5

1.25

3

1.5

8 VDC

3

1.5

6

5

2.5

14 VDC

30 VDC

6

5

125 VDC

0.5

0.4

0.4

0.05

250 VDC

0.25

0.2

0.2

0.03

High current at high VDC
switching type

8 VDC

10

3

1.5

10

5

2.5

14 VDC

30 VDC

125 VDC

7.5

6

250 VDC

3

1.5

0.75

2

1.5

2

1.5

General specifications

Durability

Mechanical

10.000.000 operations min

Electrical

500.000 operations min

Operating speed

Plunger

0.05 mm/s to 0.5 m/s

Operating frequency

Mechanical

120 operations/min

Electrical

20 operations/min

Insulation resistance

100 M Ω min (at 500VDC)

Contact resistance (initial)

15 m Ω max

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals

2,000 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part

Vibration resistance

Malfunction

10 to 55 Hz, 1.5 mm double amplitude

Shock resistance

Destruction

1,000 m/s² min

Malfunction

300 m/s² min

Ambient temperature

Operating

-10 to 80°C (with no icing)

Ambient humidity

Operating

35% to 95% RH

Degree of protection

IEC 60529: IP67

Additional specifications after EN60947-5-1 (TÜV Rheinland File No J50041904)

Category

AC-12 10A/250 VAC

Rated insulation voltage

1,000 VAC

Short circuit protective device

10A fuse type gG (IEC60269)

Protection against electrical shock

Class II

Operating characteristics

Values for OF and RF are in N and values for PT, OT, MD and OP are in mm unless otherwise specified.

ZC-D ☐

ZC-Q2 ☐

ZC-Q5 ☐

ZC-N2 ☐

ZC-W1 ☐

ZC-W21 ☐

ZC-W25 ☐

ZC-W5 ☐

Operating force (OF)

11.8

6.86

2.75

3.92

Release force (RF)

4.9

1.67

0.59

0.78

Pre-travel (PT)

1.5

Overtravel (OT)

2.4

3

2.5

8.4

6

Movement differential (MD)

0.2

1.4

1

Operating Position (OP)

32.4±0.8

47.4±0.8

38.2±0.8

47.4±0.8

28.5±1.2

43.0±1.2

28.5±1.2

Downloads