V680/V680S

Contact sales

+90 216 540 59 91

Request a Price Quote

Category:

Description

V680/V680S

3 in 1 RFID system: Antenna, Amplifier & Controller in a single compact housing

The all-in-one design of the V680S RFID system provides simple installation. Communication via a Modbus TCP connection, ideal for industrial applications, makes system expansion possible with minimal effort. Configuration via the integrated web browser interface is fast and requires no additional software or special cables.

  • Ethernet (Modbus TCP)
  • WEB browser can be used for setting, monitoring, and communications with RFID tags
  • RFID Analyser
  • Communication Diagnostic

 

Datasheet
Click for other ident systems products

Specifications & ordering info

Ordering information

V680S-series

RF tag

Type

Memory capacity

Appearance

Size

Installation

Order code

Battery-less

2 kbytes

40 × 40 × 5 mm

For flush mounting on metallic surface

V680S-D2KF67M

For flush mounting on nonmetallic surface

V680S-D2KF67

86 × 54 × 10 mm

For flush mounting on metallic surface

V680S-D2KF68M

For flush mounting on nonmetallic surface

V680S-D2KF68

8 kbytes

40 × 40 × 5 mm

For flush mounting on metallic surface

V680S-D8KF67M

For flush mounting on nonmetallic surface

V680S-D8KF67

86 × 54 × 10 mm

For flush mounting on metallic surface

V680S-D8KF68M

For flush mounting on nonmetallic surface

V680S-D8KF68

V680-series

RF tag

Type

Memory capacity

Appearance

Size

Installation

Order code

Battery-less

1 kbyte

20 dia. × 2.7 mm

For flush mounting on nonmetallic surface

V680-D1KP54T

34 × 34 × 3.5 mm

For flush mounting on metallic surface

V680-D1KP66MT

For flush mounting on nonmetallic surface

V680-D1KP66T

Environment-resistant type Battery-less

95 × 36.5 × 6.5 mm

For flush mounting on nonmetallic surface

V680-D1KP66T-SP

High-temperature type Battery-less

80 dia. × t10 mm

For mounting with special attachment

V680-D1KP58HTN

Note: V680 series 8kbyte RF Tag (V680-D8KF67,V680-D8KF67M and V680-D8KF68A) can communicate with V680S series Reader/Writer. For details, refer to the User’s Manual (Cat. No. Z339).

Reader/Writer

Type

Appearance

Size

Network

Order code

Reader/Writer

50 × 50 × 30 mm

EtherNet/IP

V680S-HMD63-EIP

PROFINET

V680S-HMD63-PNT

75 × 75 × 40 mm

EtherNet/IP

V680S-HMD64-EIP

PROFINET

V680S-HMD64-PNT

120 × 120 × 40 mm

EtherNet/IP

V680S-HMD66-EIP

PROFINET

V680S-HMD66-PNT

50 × 50 × 30 mm

Modbus TCP (TCP/IP)

V680S-HMD63-ETN

75 × 75 × 40 mm

V680S-HMD64-ETN

120 × 120 × 40 mm

V680S-HMD66-ETN

RF tag attachment

Type

Appearance

Order code

For the V680-D1KP66T

V600-A86

For the V680-D1KP58HTN

V680-A80

For the V680-D1KP54T

V700-A80

Cable

Type

Appearance

Length

Order code

Special connector — RJ45

2 m

V680S-A41 2M

5 m

V680S-A41 5M

10 m

V680S-A41 10M

Special connector — Loose wires

2 m

V680S-A42 2M

5 m

V680S-A42 5M

10 m

V680S-A42 10M

Extension cable

Type

Appearance

Length

Order code

Special connector — Special connector

10 m

V680S-A40 10M

20 m

V680S-A40 20M

50 m

V680S-A40 50M

Note: The maximum extendable cable length using the cable and extension cable is 60 m. Only one extension cable can be used.

Industrial switching hubs (Recommended hubs)

Type

Appearance

Specifications

Order code

Functions

No. of ports

Failure detection

Industrial switching hubs

Quality of Service (QoS):
EtherNet/IP control data priority

Failure detection:
Broadcast storm and LSI error detection
10/100BASE-TX, Auto-Negotiation

3

No

W4S1-03B

5

No

W4S1-05B

5

Yes

W4S1-05C

Specifications

V680S-series

RF tag (2-kbyte Memory)

Item

V680S-D2KF67

V680S-D2KF67M

V680S-D2KF68

V680S-D2KF68M

Memory capacity

2,000bytes (user area)

Memory type

FRAM

Data retention

10 years after writing (85°C or less)

Memory life

One trillion writes for each block (85°C or less), Access frequency

: One trillion accesses

Ambient operating temperature

 20 to 85°C (with no icing)

Ambient storage temperature

 40 to 125°C (with no icing)

Ambient operating humidity

35% to 85%

Degree of protection

IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)

.

IPX9K (DIN 40 050)

Vibration resistance

No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each

No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)

Dimensions (W×H×D)

40 × 40 × 5 mm

86 × 54 × 10 mm

Materials

Exterior: PPS resin

Weight

Approx. 11.5 g

Approx. 12 g

Approx. 44 g

Approx. 46 g

Metal countermeasures

None

Provided

None

Provided

Note: For details, refer to the User’s Manual (Cat. No. Z339).

RF Tag (8-kbyte Memory)

Item

V680S-D8KF67

V680S-D8KF67M

V680S-D8KF68

V680S-D8KF68M

Memory capacity

8,192 bytes (user area)

Memory type

FRAM

Data retention

10 years after writing (85°C or less)

Memory life

One trillion writes for each block (85°C or less), Access frequency

: One trillion accesses

Ambient operating temperature

 20 to 85°C (with no icing)

Ambient storage temperature

 40 to 125°C (with no icing)

Ambient operating humidity

35% to 85%

Degree of protection

IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)

.

IPX9K (DIN 40 050)

Vibration resistance

No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each

No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)

Dimensions (W×H×D)

40 × 40 × 5 mm

86 × 54 × 10 mm

Materials

Exterior: PPS resin

Weight

Approx. 11.5 g

Approx. 12 g

Approx. 44 g

Approx. 46 g

Metal countermeasures

None

Provided

None

Provided

Note: For details, refer to the User’s Manual (Cat. No. Z339).

V680-series

RF Tag (1-kbyte Memory)

Item

V680-D1KP54T

V680-D1KP66T

V680-D1KP66MT

V680-D1KP66T-SP

Memory capacity

1,000 bytes (user area)

Memory type

EEPROM

Data retention time

10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C)

Total data retention at high temperatures exceeding 125°C is 10 hours

10 years after writing (85°C or less)

Write endurance

100,000 writes for each block (25°C)

Ambient operating temperature
(during transmission)

 25 to 85°C (with no icing)

During RF Tag communications:
 25 to 70°C (with no icing)

Not during RF Tag communications:
 40 to 110°C (with no icing)

Ambient storage temperature
(during data backup)

 40 to 125°C (with no icing)

Heat resistance: 1,000 thermal cycles each of 30 minutes at  10°C/150°C,

High temperature storage: 1,000 hours at 150°C

200 thermal cycles each of 30 minutes at  10°C/180°C,

High temperature storage: 200 hours at 180°C

 40 to 110°C (with no icing)

Ambient operating humidity

35 to 95%

Degree of protection

IP67 (IEC 60529:2001)

Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)

IP68 (IEC 60529:2001)

Oil resistance equivalent to IP67G

(JIS C 0920:2003, Appendix 1)

IP67

Vibration resistance

No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,

acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)

Appearance

20 dia. × 2.7 mm

34 × 34 × 3.5 mm

95 × 36.5 × 6.5 mm
(excluding protruding parts)

Materials

PPS resin

Exterior: PFA fluororesin

RF Tag filling: PPS resin

Weight

Approx. 2 g

Approx. 6 g

Approx. 7.5 g

Approx. 20 g

Metal countermeasures

None

None

Provided

None

Note: For details, refer to the User’s Manual (Cat. No. Z339).

RF Tag (1-kbyte Memory with High-temperature Capability)

Item

V680-D1KP58HTN

Memory capacity

1,000 bytes (user area)

Memory type

EEPROM

Data retention

10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C)

Total data retention at high temperatures exceeding 125°C is 10 hours

Write endurance

100,000 writes for each block (25°C)

Ambient operating temperature
(during transmission)

 25 to 85°C (with no icing)

Ambient storage temperature
(during data backup)

 40 to 250°C (with no icing)
(Data retention:  40 to 125°C)

Ambient storage humidity

No restrictions.

Degree of protection

IP67 (IEC 60529:2001)

Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)

Vibration resistance

No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s²,

10 sweeps each in X, Y, and Z directions for 15 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)

Materials

Exterior: PPS resin

Weight

Approx. 70 g

Note: For details, refer to the User’s Manual (Cat. No. Z339).

Reader/Writer

EtherNet/IP, PROFINET

Item

V680S-HMD63-EIP

V680S-HMD63-PNT

V680S-HMD64-EIP

V680S-HMD64-PNT

V680S-HMD66-EIP

V680S-HMD66-PNT

Dimensions (W×H×D)

50 × 50 × 30 mm
(excluding protruding parts and cables)

75 × 75 × 40 mm
(excluding protruding parts and cables)

120 × 120 × 40 mm
(excluding protruding parts and cables)

Power supply voltage

24 VDC ( − 15% to 10%)

Consumption current

0.2 A max.

Ambient operating temperature

 10 to + 55°C (with no icing)

Ambient operating humidity

25% to 85% (with no condensation)

Ambient storage temperature

 25 to 70°C (with no icing)

Ambient storage humidity

25% to 85% (with no condensation)

Insulation resistance

20 M Ω min. (at 500 VDC) between cable terminals and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between cable terminals and case

Vibration resistance

No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times)

Degree of protection

IP67 (IEC 60529: 2001)

Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1)

Materials

Case: PBT resin, Filled resin: Urethane resin

Mass

Approx. 240 g

Approx. 390 g

Approx. 760 g

Installation method

Reader/Writer: Two M4 screws
(Use a screw of 12 mm or more in length.)

Branch cable joint: One M4 screws

Four M4 screws
(Use a screw of 12 mm or more in length.)

Host device communications interface

Ethernet 10BASE-T/100BASE-TX

Host device communications protocol

EtherNet/IP, PROFINET

Accessories

Instruction Sheet, Description of Regulations and Standard, IP address label

Note: The 0.5 m cable with two M12 connectors is attached to the Reader/Writer. The cable cannot be removed.

Modbus TCP

Item

V680S-HMD63-ETN

V680S-HMD64-ETN

V680S-HMD66-ETN

Dimensions

50 × 50 × 30
(excluding protruding parts)

75 × 75 × 40
(excluding protruding parts)

120 × 120 × 40 mm
(excluding protruding parts)

Power supply voltage

24 VDC (-15% to 10%)

Consumption current

0.2A max.

Ambient operating temperature

-10 to 55°C (with no icing)

Ambient operating humidity

25% to 85% (with no condensation)

Ambient storage temperature

 25 to 70°C (with no icing)

Ambient storage humidity

25% to 85% (with no condensation)

Insulation resistance

20 M Ω min. (at 500 VDC) between cable terminals and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between cable terminals and case

Vibration resistance

No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each

Shock resistance

No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times)

Degree of protection

IP67 (IEC 60529: 2001)

Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1)

Materials

Case: PBT resin, Filled resin: Urethane resin

Mass

Approx. 120 g

Approx. 270 g

Approx. 640 g

Installation method

Two M4 screws
(Use a screw of 12 mm or more in length.)

Four M4 screws
(Use a screw of 12 mm or more in length.)

Host device communications interface

Ethernet 10BASE-T/100BASE-TX

Host device communications protocol

MODBUS TCP

Accessories

Instruction sheet, Description of Regulations and Standard, IP address label, Ferrite core

System configuration

The below shows the configuration for 1 to 1 connection. Multiple Reader/Writers can be connected by using a switching hub.

EtherNet/IP, PROFINET

Modbus TCP

Downloads

Brochures


Connection guide


Device description files (ZIP)


Datasheet


Manuals