S8VK-T

Contact sales

+90 216 540 59 91

Request a Price Quote

Category:

Description

S8VK-T

Compact 3-phase input power supply

The 3 phase S8VK-T series adds to the compact Power Supply range (from 120W up to 960W), giving you the best footprint size. Just like the single phase type S8VK-G. It has the wide acceptable input range including 3-Phase input (3 x 340 to 576 VAC)  2-Phase input (2 X 340 to 576 VAC) and DC input excluding 960W (450 to 810 VDC)

  • Wide operating temperature range (-40 to +70ºC) to guarantee operation stability
  • Double set of DC output terminals (three for the negative) to provide easy wiring
  • High efficiency (90%) to reduce energy consumption
  • Power Boost functionality (120%)
  • High vibration resistance with Metal DIN-rail mounting clip.

Specifications & ordering info

Ordering information

Type

Power ratings

Input voltage

Output voltage

Output current

Size (W × H × D) [mm]

Order code

Standard models

Coated models

Power supply three-phase

120 W

3 × 380 to 480 VAC,
2 × 380 to 480 VAC
450 to 600 VDC (Excluding 960 W)

Allowable range:
3 × 320 to 576 VAC,
2 × 340 to 576 VAC,
450 to 810 VDC (Excluding 960 W)

24 V

5 A

40×125×113

S8VK-T12024

S8VK-T12024-400

240 W

10 A

60×125×140

S8VK-T24024

S8VK-T24024-400

480 W

20 A

95×125×140

S8VK-T48024

S8VK-T48024-400

960 W

40 A

135×125×170

S8VK-T96024

S8VK-T96024-400

Specifications

Item

120 W

240 W

480 W

960 W

Efficiency (Typ. at 400 VAC)

89%

89%

91%

92%

Input

Rated Input Voltage

3 × 380 to 480 VAC, 2 × 380 to 480 VAC, 450 to 600 VDC

3 × 380 to 480 VAC,
2 × 380 to 480 VAC

Allowable range

3 × 320 to 576 VAC, 2 × 340 to 576 VAC, 450 to 810 VDC

3 × 320 to 576 VAC,
2 × 340 to 576 VAC

Output

Voltage adjustment range (with V.ADJ)

22.5 to 29.5 V

Input variation influence

0.5% max. (at 3 × 320 to 576 VAC input, 100% load)

Load variation Influence

1.5% max. at 0 to 100% load

Temperature variation influence

0.05%/°C max.

Overload protection

Yes, 125% of rated current typ.

Power Boost

120% of rated current

Overvoltage protection

Yes

Operating ambient temperature

−40 to 70°C (−40 to 158°F)

Series Operation

Yes, Up to 2 units

Parallel Operation

Yes, Up to 2 units

EMI

Conforms to EN 61204-3, EN 55011 Class B

EMS

Conforms to EN 61204-3 high severity levels

Harmonic current emissions

Conforms to EN 61000-3-2

Approved Standards

UL: UL 508 (Listing),

ANSI/ISA 12.12.01

EN/VDE: EN 50178,

Lloyd’s Register

UL: UL 508 (Listing), ANSI/ISA 12.12.01, UL 60950-1, CSA: C22.2 No.60950-1,

EN/VDE: EN 50178, EN 60950-1,

Lloyd’s Register

Fulfilled Standards

SELV (EN 50178), PELV (EN 60204-1, EN 50178),
Safety of Power Transformers (EN 61558-2-16), EN 50274 for Terminal parts

SELV (EN 60950-1/EN 50178/UL 60950-1), PELV (EN 60204-1, EN 50178),

Safety of Power Transformers (EN 61558-2-16), EN 50274 for Terminal parts

Degree of protection

IP20 by EN / IEC 60529

Downloads

Brochures


Datasheet