Model
|
F3SJ-A ____ P14
|
F3SJ-A ____ P30
|
Input voltage
|
Test input, interlock selection input, reset input, and muting input are all
ON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or open
External device monitoring input
ON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open
|
Indicator
|
Emitter
|
Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity
Error mode indicators (red LED × 3): Blink to indicate error details
Power indicator (green LED × 1): ON while power is on
Interlock indicator (yellow LED × 1): ON while under interlock, blinks at lockout.
External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED × 2):
ON/flash according to function
|
Receiver
|
Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity
Error mode indicators (red LED × 3): Blink to indicate error details
OFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.
ON output indicator (green LED × 1): ON while safety output is ON
Muting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
|
Mutual interference prevention function
|
Interference light prevention algorithm, sensing distance change function
|
Series connection
|
Time division emission by series connection
Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected.
Total number of beams: up to 400 beams
Maximum cable length for 2 sets: no longer than 15 m
|
Test function
|
Self test (at power-ON and at power distribution)
External test (emission stop function by test input)
|
Safety-related functions
|
Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)
External device monitor
Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)
Fixed blanking (must be set by a setting tool)
Floating blanking (must be set by a setting tool)
|
Connection method
|
Connector method (M12, 8-pin)
|
Protection circuit
|
Output short-circuit protection, and power supply reverse polarity protection
|
Ambient temperature
|
Operating: -10 to 55°C (no icing), Storage: -30 to 70°C
|
Ambient humidity
|
Operating: 35% to 85% (no condensation), Storage: 35% to 95%
|
Operating ambient light intensity
|
Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max.
|
Insulation resistance
|
20 MΩ min. (at 500 VDC)
|
Withstand voltage
|
1,000 VAC 50/60 Hz, 1 min
|
Degree of protection
|
IP65 (IEC 60529)
|
Vibration resistance
|
Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
|
Shock resistance
|
Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
|
Material
|
Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
|
Weight (packaged)
|
Calculate using the following expressions:
(1) For F3SJ-A ____ 14, weight (g) = (protective height) x 1.7 + α
(2) F3SJ-A ____ 30, weight (g) = (protective height) x 1.5 + α
The values for α are as follows:
Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400
Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600
Protected height 1,136 to 1,658 mm: = 2,000
|
Accessories
|
Test rod ( * 1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) ( * 2), error mode label, User’s Manual (CD-ROM)
* 1. The F3SJ-A ☐☐☐☐ 55 is not included.
* 2. Number of intermediate brackets depends on protective height of F3SJ.
For protective height from 600 to 1,130 mm : 1 set for each of the emitter and receiver is included
For protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are included
For protective height from 1,660 to 2,180 mm : 3 sets for each of the emitter and receiver are included
For protective height from 2,195 to 2,500 mm : 4 sets for each of the emitter and receiver are included
|
Applicable standards
|
IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)
IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
|