Açıklama
Omron F39-TGR-MCL; Muting aktüatörleri
Omron F39-TGR-MCL -_ muting aktüatörleri, F3S-TGR-CL Güvenlik Sensörleri için tak ve çalıştır özellikli aksesuarlardır. Tüm muting sistemi için kolay kablolama, gerekli tüm bağlantıların yöneten bağlantı kutularıyla sağlanır.
- Aktif/aktif ve aktif/pasif sistemler desteklenir
- Aynı parçalar kullanılarak T ve L şekilli muting
- Seçilebilir çoklu sensör sırası
- Önceden monte edilmiş montaj braketleri
- Önceden bağlanmış bağlantı kabloları
- Tip 2 ve Tip 4 uygulamalarını destekler
Özellikler ve sipariş bilgisi
Muting actuators (mounting brackets are included)
|
|
Order code
|
Transmitter + Receiver set
|
active/active
|
F39-TGR-MCL
|
Receiver only
|
active/active
|
F39-TGR-MCL-D
|
Transmitter only
|
active/active
|
F39-TGR-MCL-L
|
Transceiver + Reflector set
|
active/passive
|
F39-TGR-MCL-R
|
Transceiver only
|
active/passive
|
F39-TGR-MCL-R-A
|
Reflector only
|
active/passive
|
F39-TGR-MCL-R-P
|
Connection boxes
|
Order code
|
Connection box for Receivers and Transceivers
|
F39-TGR-MCL-CMD
|
Connection box for Transmitters
|
F39-TGR-MCL-CML
|
Mounting brackets
|
Order code
|
Mounting bracket for one muting actuator
|
F39-TGR-MCL-ST
|
Specifications
Power supply
|
24 VDC±20%
|
Consumption
|
5 W max (F39-TGR-MCL-_ only)
|
Ambient temperature
|
During operation; -10 to + 55°C (with no dew condensation)
|
Cable connector
|
Length
|
30 cm pre-wired
|
RX
|
M12 5-pin female
|
TX
|
M12 5-pin female
|
Degree of protection
|
IP65
|
Distance between muting beams
|
250mm
|
F39-TGR-MCL
|
Optical data
|
Through-beam system
|
Operating distance
|
0 … 7 m; max. 0 … 8,4 m
|
Light source
|
Red emitting LEDs, Wavelength 630 nm
|
F39-TGR-MCL-R
|
Optical data
|
Polarized retro-reflective system
|
Operating distance
|
0 … 4 m; max. 0 … 4,8 m
|
Light source
|
Red emitting LEDs, Wavelength 660 nm
|
Configuration examples
L-muting, active/active
1) Safety sensor (e.g. F3S-TGR-CL4A-K2-500)
2) Muting actuators F39-TGR-MCL
3) Connector box F39-TGR-MCL-CML
4) Connector box F39-TGR-MCL-CMD
L-muting, active/passive
1) Safety Sensor (e.g. F3S-TGR-CL4A-K2C-500)
2) Muting actuators F39-TGR-MCL-R
3) Connection box F39-TGR-MCL-CMD