Description
E3NX-FA
High-performance digital fiber amplifier
The E3NX-FA amplifier is best choice for most challenging fiber applications in terms of long sensing distance, minute object detection or high speed processes.
- Easy teaching by Smart tuning within a few seconds
- New N-Smart technology provides significant improvement for sensing distance, minimum object detection and speed
- Easy and transparent information about sensor status by Solution Viewer and Change Finder function
- EtherCAT Communication unit for high-speed field bus connectivity
Features
N-Smart technology
The GIGA RAY 2S high-efficiency coupling element achieves a clear signal and wide dynamic range. It is joined by the new “Smart Noise Reduction” light reception algorithm and the high-speed, high-precision “N-Core” IC.These three technologies improve the basic performance of E3NX-FA resulting in signal-to-noise ratio that is 2.5 times higher compared to conventional models.
Dynamic Power Control
Dynamic Power Control (DPC) automatically compensates differences in the incident level caused by dirt or vibration. In addition an alarm output signal is sent for predictive maintenance, if the sensor has reached compensation limit.
Timer functions
Adjust the output signal length and timing:
- T1 ON-delay set time
- T2 OFF-delay set time
- T1 and T2 can be set separately
Specifications & ordering info
Fiber Amplifier Units
Type
|
Connecting method
|
Inputs/outputs
|
Order code
|
NPN output
|
PNP output
|
Standard models
|
Pre-wired (2 m)
|
1 output
|
E3NX-FA11 2M
|
E3NX-FA41 2M
|
E3NX-FA11-5 2M
|
−
|
Wire-saving Connector
|
1 output
|
E3NX-FA6
|
E3NX-FA8
|
Advanced models
|
Pre-wired (2 m)
|
2 outputs + 1 input
|
E3NX-FA21 2M
|
E3NX-FA51 2M
|
Wire-saving Connector
|
1 output + 1 input
|
E3NX-FA7
|
E3NX-FA9
|
2 outputs
|
E3NX-FA7TW
|
E3NX-FA9TW
|
M8 Connector
|
1 output + 1 input
|
E3NX-FA24
|
E3NX-FA54
|
2 outputs
|
−
|
E3NX-FA54TW
|
Infrared models
|
Pre-wired (2 m)
|
1 output
|
E3NX-FAH11 2M
|
E3NX-FAH41 2M
|
Wire-saving Connector
|
1 output
|
E3NX-FAH6
|
E3NX-FAH8
|
Analog output models
|
Pre-wired (2 m)
|
2 outputs
|
E3NX-FA11AN 2M
|
E3NX-FA41AN 2M
|
Model for Sensor Communications Unit
|
Connector for Sensor Communications Unit
|
−
|
E3NX-FA0
|
E3NX-FAH0
|
Accessories (Sold Separately)
Fiber amplifier connectors
Type
|
Appearance
|
Cable length
|
No. of conductors
|
Applicable Fiber Amplifier Units
|
Order code
|
Master Connector
|
|
2 m
|
4
|
E3NX-FA7
E3NX-FA7TW
E3NX-FA9
E3NX-FA9TW
|
E3X-CN21
|
Slave Connector
|
2
|
E3X-CN22
|
Master Connector
|
3
|
E3NX-FA6
E3NX-FA8
|
E3X-CN11
|
Slave Connector
|
1
|
E3X-CN12
|
Size
|
Cable
|
Appearance
|
Cable type
|
Order code
|
M8
|
Standard cable
|
Straight
|
2 m
|
4-wire
|
XS3F-M421-402-A
|
5 m
|
XS3F-M421-405-A
|
L-shaped
|
2 m
|
XS3F-M422-402-A
|
5 m
|
XS3F-M422-405-A
|
Communication units
Type
|
Appearance
|
Order code
|
Sensor Communications Unit for EtherCAT
|
|
E3NW-ECT
|
Sensor Communications Unit for CompoNet
|
|
E3NW-CRT
|
Sensor Communications Unit for CC-Link
|
E3NW-CCL
|
Distributed Sensor Unit
|
|
E3NW-DS
|
Note: Refer to your OMRON website for details.
Specifications
Standard models/ Advanced models/ Infrared models
Type
|
Standard models
|
Advanced models
|
Infrared models
|
NPN output
|
E3NX-FA11
|
E3NX-FA6
|
E3NX-FA11-5
|
E3NX-FA21
|
E3NX-FA7
|
E3NX-FA7TW
|
E3NX-FA24
|
−
|
E3NX-FAH11
|
E3NX-FAH6
|
PNP output
|
E3NX-FA41
|
E3NX-FA8
|
−
|
E3NX-FA51
|
E3NX-FA9
|
E3NX-FA9TW
|
E3NX-FA54
|
E3NX-FA54TW
|
E3NX-FAH41
|
E3NX-FAH8
|
Connecting method
|
Pre-wired
|
Wire-saving Connector
|
Pre-wired
|
Pre-wired
|
Wire-saving Connector
|
M8 Connector
|
Pre-wired
|
Wire-saving Connector
|
Inputs/outputs
|
Outputs
|
1 output
|
2 outputs
|
1 output
|
2 outputs
|
1 output
|
2 outputs
|
1 outputs
|
External inputs
|
−
|
1 input
|
1 input
|
−
|
1 input
|
−
|
−
|
Light source (wavelength)
|
Red, 4-element LED (625 nm)
|
Infrared LED (870 nm)
|
Power supply voltage
|
10 to 30 VDC, including 10% ripple (p-p)
|
Protection circuits
|
Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection
|
Response time
|
Super-high-speed mode (SHS)
|
Operate or reset for model with 1 output: 30 µs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 µs each), with 2 outputs: 32 µs
|
High-speed mode (HS)
|
Operate or reset: 250 µs
|
Standard mode (Stnd)
|
Operate or reset: 1 ms
|
Giga-power mode (GIGA)
|
Operate or reset: 16 ms
|
Sensitivity adjustment
|
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (−99% to 99%)) or manual adjustment
|
Maximum connectable Units
|
30
|
No. of Units for mutual interference prevention
|
Super-high-speed mode (SHS)
|
0
2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.
|
High-speed mode (HS)
|
10
|
Standard mode (Stnd)
|
10
|
Giga-power mode (GIGA)
|
10
|
Functions
|
Automatic power control (APC), Dynamic power control (DPC), Timer, Zero reset, Resetting settings, Eco mode, Bank switching, Power tuning
|
Analog output models/Model for Sensor Communications Unit
Type
|
Analog output models
|
Model for Sensor Communications Unit
|
NPN output
|
E3NX-FA11AN
|
E3NX-FA0
|
E3NX-FAH0
|
PNP output
|
E3NX-FA41AN
|
Connecting method
|
Pre-wired
|
Connector for Sensor Communications Unit
|
Inputs/outputs
|
Outputs
|
2 outputs
|
−
|
−
|
External inputs
|
−
|
Light source (wavelength)
|
Red, 4-element LED (625 nm)
|
Infrared LED (870 nm)
|
Power supply voltage
|
10 to 30 VDC, including 10% ripple (p-p)
|
Supplied from the connector through the communication units.
|
Control output
|
Load power supply voltage:
30 VDC max., open-collector output
(depends on the NPN/PNP output format)
Load current:
Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max.
(Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.)
OFF current: 0.1 mA max.
|
−
|
Analog output
|
Voltage output: 1-5 VDC (10 kΩ or more connected load), temperature characteristics:
0.3% F.S. / °C
|
−
|
Control output
Response time
|
Super-high-speed mode (SHS)
|
Operate or reset: 80 µs
|
Operate or reset: 32 µs
|
High-speed mode (HS)
|
Operate or reset: 250 µs
|
Operate or reset: 250 µs
|
Standard mode (Stnd)
|
Operate or reset: 1 ms
|
Operate or reset: 1 ms
|
Giga-power mode (GIGA)
|
Operate or reset: 16 ms
|
Operate or reset: 16 ms
|
Sensitivity adjustment
|
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, percentage tuning (-99% to 99%)) or manual adjustment
|
Maximum connectable Units
|
30
|
With E3NW-ECT: 30 units (When connected to an OMRON NJ-series Controller.)
With E3NW-CRT: 16 units (Note: E3NX-FAH0 can not be connected.)
With E3NW-CCL: 16 units
|
No. of Units for mutual interference prevention
|
Super-high-speed mode (SHS)
|
0 (The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.)
|
High-speed mode (HS)
|
10
|
Standard mode (Stnd)
|
10
|
Giga-power mode (GIGA)
|
10
|
Functions
|
Automatic power control (APC), Dynamic power control (DPC), Timer, Zero reset, Resetting settings, Eco mode, Bank switching, Power tuning
|
Easy One-Button-Teaching/Smart Tuning
Easy setting of optimum power and threshold by pushing tune button twice.
Smart power control
Enhanced signal stability control for compensating power reductions caused by temperature drift, dust or aging of LED. Alarm output added for predictive maintenance.
N-Smart platform
The N-Smart platform provides wide portfolio of advanced sensors − all with the same intuitive operation concept and field bus connectivity.