Açıklama
Omron SX-AFE; Yüksek performanslı Vektör Kontrolü
Omron SX-AFE; Nominal değerler 400 V sınıfı trifaze: 55 ila 900 kW 690 V sınıfı trifaze: 110 ila 1.100 kW
- Düşük harmonik veya rejeneratif sürücü
- IP54 tam aralık
- Kompakt ve sağlam tasarım
- Yerleşik filtre (C3 sınıfına uygun)
- Yerleşik sigortalar (200 kW’den itibaren)
- EN 13849-1 ve EN 62061 standartlarına uygun güvenlik
- Esneklik seçenekleri: I/O‘lar, Fieldbus, PTC/PT100
- İletişim seçenekleri: EtherCAT, PROFINET, Modbus, DeviceNet, PROFIBUS, Modbus TCP
- CE, UL, RoHS
Değerler
400 V sınıfı üç fazlı: 55 – 900 kW
690 V sınıfı üç fazlı: 110 – 1.100 kW
Özellikler ve sipariş bilgisi
Ordering information
Inverter with Regenerative Active Front End
Specifications
|
IP54 model
|
Low harmonic drive
|
Regenerative + low harmonic drive
|
Voltage
|
Heavy duty
|
Normal duty
|
Direct torque control
|
V/F control
|
Direct torque control
|
400 V
|
45 kW
|
87 A
|
55 kW
|
109 A
|
SX-D4055-E1FL
|
SX-D4055-E1VL
|
SX-D4055-E1FR
|
55 kW
|
117 A
|
75 kW
|
146 A
|
SX-D4075-E1FL
|
SX-D4075-E1VL
|
SX-D4075-E1FR
|
75 kW
|
140 A
|
90 kW
|
175 A
|
SX-D4090-E1FL
|
SX-D4090-E1VL
|
SX-D4090-E1FR
|
90 kW
|
168 A
|
110 kW
|
210 A
|
SX-D4110-E1FL
|
SX-D4110-E1VL
|
SX-D4110-E1FR
|
110 kW
|
200 A
|
132 kW
|
250 A
|
SX-D4132-E1FL
|
SX-D4132-E1VL
|
SX-D4132-E1FR
|
132 kW
|
240 A
|
160 kW
|
300 A
|
SX-D4160-E1FL
|
SX-D4160-E1VL
|
SX-D4160-E1FR
|
160 kW
|
300 A
|
200 kW
|
375 A
|
SX-D4200-E1FL
|
SX-D4200-E1VL
|
SX-D4200-E1FR
|
200 kW
|
344 A
|
220 kW
|
430 A
|
SX-D4220-E1FL
|
SX-D4220-E1VL
|
SX-D4220-E1FR
|
220 kW
|
400 A
|
250 kW
|
500 A
|
SX-D4250-E1FL
|
SX-D4250-E1VL
|
SX-D4250-E1FR
|
250 kW
|
480 A
|
315 kW
|
600 A
|
SX-D4315-E1FL
|
SX-D4315-E1VL
|
SX-D4315-E1FR
|
315 kW
|
520 A
|
355 kW
|
650 A
|
SX-D4355-E1FL
|
SX-D4355-E1VL
|
SX-D4355-E1FR
|
355 kW
|
600 A
|
400 kW
|
750 A
|
SX-D4400-E1FL
|
SX-D4400-E1VL
|
SX-D4400-E1FR
|
400 kW
|
688 A
|
450 kW
|
860 A
|
SX-D4450-E1FL
|
SX-D4450-E1VL
|
SX-D4450-E1FR
|
450 kW
|
800 A
|
560 kW
|
1,000 A
|
SX-D4560-E1FL
|
SX-D4560-E1VL
|
SX-D4560-E1FR
|
500 kW
|
960 A
|
630 kW
|
1,200 A
|
SX-D4630-E1FL
|
SX-D4630-E1VL
|
SX-D4630-E1FR
|
630 kW
|
1,200 A
|
800 kW
|
1,500 A
|
SX-D4800-E1FL
|
SX-D4800-E1VL
|
SX-D4800-E1FR
|
800 kW
|
1,400 A
|
900 kW
|
1,750 A
|
SX-D4900-E1FL
|
SX-D4900-E1VL
|
SX-D4900-E1FR
|
690 V
|
90 kW
|
87 A
|
110 kW
|
109 A
|
SX-D6110-E1FL
|
SX-D6110-E1VL
|
SX-D6110-E1FR
|
110 kW
|
117 A
|
132 kW
|
146 A
|
SX-D6132-E1FL
|
SX-D6132-E1VL
|
SX-D6132-E1FR
|
132 kW
|
148 A
|
160 kW
|
185 A
|
SX-D6160-E1FL
|
SX-D6160-E1VL
|
SX-D6160-E1FR
|
200 kW
|
200 A
|
250 kW
|
250 A
|
SX-D6250-E1FL
|
SX-D6250-E1VL
|
SX-D6250-E1FR
|
250 kW
|
240 A
|
315 kW
|
300 A
|
SX-D6315-E1FL
|
SX-D6315-E1VL
|
SX-D6315-E1FR
|
315 kW
|
300 A
|
355 kW
|
375 A
|
SX-D6355-E1FL
|
SX-D6355-E1VL
|
SX-D6355-E1FR
|
355 kW
|
344 A
|
450 kW
|
430 A
|
SX-D6450-E1FL
|
SX-D6450-E1VL
|
SX-D6450-E1FR
|
450 kW
|
448 A
|
560 kW
|
560 A
|
SX-D6560-E1FL
|
SX-D6560-E1VL
|
SX-D6560-E1FR
|
600 kW
|
600 A
|
710 kW
|
750 A
|
SX-D6710-E1FL
|
SX-D6710-E1VL
|
SX-D6710-E1FR
|
800 kW
|
800 A
|
1,000 kW
|
1,000 A
|
SX-D61K0-E1FL
|
SX-D61K0-E1VL
|
SX-D61K0-E1FR
|
900 kW
|
896 A
|
1,100 kW
|
1,120 A
|
SX-D61K1-E1FL
|
SX-D61K1-E1VL
|
SX-D61K1-E1FR
|
DC Supply with Regenerative Active Front End
Specifications
|
Order code
|
Voltage
|
Normal duty
|
400 V
|
115 kW
|
175 A
|
SX-D4115-E1AR
|
165 kW
|
250 A
|
SX-D4165-E1AR
|
250 kW
|
375 A
|
SX-D4250-E1AR
|
330 kW
|
500 A
|
SX-D4330-E1AR
|
500 kW
|
750 A
|
SX-D4500-E1AR
|
660 kW
|
1,000 A
|
SX-D4660-E1AR
|
1,000 kW
|
1,500 A
|
SX-D41K0-E1AR
|
690 V
|
200 kW
|
175 A
|
SX-D6200-E1AR
|
400 kW
|
350 A
|
SX-D6400-E1AR
|
600 kW
|
525 A
|
SX-D6600-E1AR
|
800 kW
|
700 A
|
SX-D6800-E1AR
|
1,200 kW
|
1,050 A
|
SX-D61K2-E1AR
|
① Panel kit
Description
|
Function
|
Order code
|
Panel kit
|
Panel kit
|
Complete panel kit including operator
|
SX-OP02-00-E
|
Blank panel kit
|
Complete panel kit including a blank operator
|
SX-OP02-01-E
|
Operator
|
Handheld control panel
|
Complete handheld control panel
|
SX-OPHH-00-E
|
Digital operator
|
Inverter digital operator
|
SX-OP01-00-E
|
Blank operator
|
Inverter blank operator
|
SX-OP01-11-E
|
② I/O option board
Description
|
Function
|
Order code
|
Additional I/O option
|
Provides 3 extra relay outputs and 3 additional digital inputs
|
01-3876-01
|
Crane option
|
Dedicated option board for crane application, including additional I/O and functions
|
01-3876-07
|
③ Communication option board
Description
|
Function
|
Order code
|
RS232/485
|
MODBUS RTU serial communication by RS232 or RS485 interface with galvanic isolation
|
01-3876-04
|
PROFIBUS-DP
|
Used for operating the inverter through PROFIBUS-DP communication with the host controller
|
01-3876-05
|
DeviceNet
|
Used for operating the inverter through DeviceNet communication with the host controller
|
01-3876-06
|
Modbus/TCP, Ethernet
|
Used for operating the inverter through Modbus/TCP communication with the host controller
|
01-3876-09
|
EtherCAT
|
Used for operating the inverter through EtherCAT communication with the host controller
|
01-3876-10
|
PROFINET (1-port)
|
Used for operating the inverter through PROFINET communication with the host controller
|
01-3876-11
|
PROFINET (2-ports)
|
01-3876-12
|
④ Encoder feedback option board
Description
|
Function
|
Order code
|
Encoder option
|
Used for connection of the actual motor speed via encoder
Up to 100 kHz with TTL and HTL incremental encoders with 5/24 V power supply
|
01-3876-03
|
⑤ PTC/PT100 option board
Description
|
Function
|
Order code
|
Thermal protection
|
Allows to connect a motor thermistor to the inverter
|
01-3876-08
|
Specifications
Common specifications
Model number: SX_
|
Specifications
|
General specifications
|
Mains voltage
|
400 V models
|
380 to 460 V, +10%/−15%
|
690 V models
|
480 to 690 V, +10%/−15%
|
Frequency
|
48 to 52 Hz and 58 to 62 Hz
|
Input total power factor
|
1.0
|
Output AC voltage
|
Inverter
|
(0-1.2) * mains supply voltage
|
Output DC voltage
|
DC Supply
|
(1.0-1.2) *√2 * mains supply voltage
|
Output frequency
|
Inverter
|
0 to 400 Hz
|
Switching frequency
|
Inverter
|
3 kHz (adjustable 1.5 to 6 kHz, SX-VL only)
|
DC Supply
|
3 kHz (adjustable 3 to 6 kHz)
|
Efficiency at nominal load
|
Inverter
|
97%
|
DC Supply
|
98%
|
Harmonics to supply, THDI
|
< 5%
|
Ambient conditions
|
Ambient temperature
|
0 to 40ºC, up to 45ºC with derating
|
Ambient humidity
|
90% RH or less (without condensation)
|
Storage temperature
|
−20 to 60ºC
|
Altitude
|
Up to 1,000 meters
|
Vibration / shock
|
According to IEC 600068-2-6, sinusoidal vibrations: 10<f<57 Hz, 0.075 mm, 57<f<150 Hz, 1 g
|
Contamination,
according to IEC 60721-3-3
|
No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materials. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2
|
Protection design
|
IP54 enclosure according to the EN 60529
|
Inverter with Regenerative Active Front End 400 V class
Three-phase: SX-D4_
|
055
|
075
|
090
|
110
|
132
|
160
|
200
|
220
|
250
|
315
|
355
|
400
|
450
|
560
|
630
|
800
|
900
|
Output
power
|
For HD setting
|
kW
|
45
|
55
|
75
|
90
|
110
|
132
|
160
|
200
|
220
|
250
|
315
|
355
|
400
|
450
|
500
|
630
|
800
|
For ND setting
|
kW
|
55
|
75
|
90
|
110
|
132
|
160
|
200
|
220
|
250
|
315
|
355
|
400
|
450
|
560
|
630
|
800
|
900
|
Output
characteristics
|
Max. output current
|
A
|
131
|
175
|
210
|
252
|
300
|
360
|
450
|
516
|
600
|
720
|
780
|
900
|
1,032
|
1,200
|
1,440
|
1,800
|
2,100
|
Rated output current at HD
|
A
|
87
|
117
|
140
|
168
|
200
|
240
|
300
|
344
|
400
|
480
|
520
|
600
|
688
|
800
|
960
|
1,200
|
1,400
|
Rated output current at ND
|
A
|
109
|
146
|
175
|
210
|
250
|
300
|
375
|
430
|
500
|
600
|
650
|
750
|
860
|
1,000
|
1,200
|
1,500
|
1,750
|
Output voltage
|
V
|
0 to Mains supply voltage
|
Max. output frequency
|
Hz
|
400 Hz
|
Power
supply
|
Rated input voltage and frequency
|
3-phase 380 to 460 V, 50/60 Hz
|
Allowable voltage fluctuation
|
10% to −15%
|
Weight
|
kg
|
380
|
400
|
480
|
500
|
500
|
700
|
750
|
830
|
880
|
1,040
|
1,210
|
1,210
|
1,370
|
1,600
|
1,700
|
2,250
|
On request
|
Note: Assembled in IP54 cabinet including main switch, main contactor and output choke.
Inverter with Regenerative Active Front End 690 V class
Three-phase: SX-D6_
|
110
|
132
|
160
|
250
|
315
|
355
|
450
|
560
|
710
|
1K0
|
1K1
|
Output
power
|
For HD setting
|
kW
|
90
|
110
|
132
|
200
|
250
|
315
|
355
|
450
|
600
|
800
|
900
|
For ND setting
|
kW
|
110
|
132
|
160
|
250
|
315
|
355
|
450
|
560
|
710
|
1,000
|
1,100
|
Output
characteristics
|
Max. output current
|
A
|
131
|
175
|
222
|
300
|
360
|
450
|
516
|
672
|
900
|
1,200
|
1,344
|
Rated output current at HD
|
A
|
87
|
117
|
148
|
200
|
240
|
300
|
344
|
448
|
600
|
800
|
896
|
Rated output current at ND
|
A
|
109
|
146
|
185
|
250
|
300
|
375
|
430
|
560
|
750
|
1,000
|
1,120
|
Output voltage
|
V
|
0 to Mains supply voltage
|
Max. output frequency
|
Hz
|
400 Hz
|
Power
supply
|
Rated input voltage and frequency
|
3-phase 480 to 690 V, 50/60 Hz
|
Allowable voltage fluctuation
|
10% to −15%
|
Weight
|
kg
|
410
|
430
|
540
|
870
|
870
|
910
|
1,350
|
1,390
|
On request
|
Note: Assembled in IP54 cabinet including main switch, main contactor or motor driven circuit breaker and output choke.
DC Supply with Regenerative Active Front End 400 V class
Three-phase: SX-D4_-E1AR
|
115
|
165
|
250
|
330
|
500
|
660
|
1K0
|
DC
power
|
For ND setting
|
kW
|
115
|
165
|
250
|
330
|
500
|
660
|
1,000
|
In/Out
characteristics
|
Max. input current
|
A
|
210
|
300
|
450
|
600
|
900
|
1,200
|
1,800
|
Rated input current at ND
|
A
|
175
|
250
|
375
|
500
|
750
|
1,000
|
1,500
|
Output voltage
|
V
|
0 to Mains supply voltage
|
Max. output frequency
|
Hz
|
400 Hz
|
Power
supply
|
Rated input voltage and frequency
|
3-phase 380 to 460 V, 50/60 Hz
|
Allowable voltage fluctuation
|
10% to −15%
|
Weight
|
kg
|
290
|
400
|
560
|
660
|
830
|
1,100
|
1,600
|
Note: Assembled in IP54 cabinet including main switch and main contactor.
DC Supply with Regenerative Active Front End 690 V class
Three-phase: SX-D6_-E1AR
|
200
|
400
|
600
|
800
|
1K2
|
DC
power
|
For ND setting
|
kW
|
200
|
400
|
600
|
800
|
1,200
|
In/Out
characteristics
|
Max. input current
|
A
|
210
|
420
|
630
|
840
|
1,260
|
Rated input current at ND
|
A
|
175
|
350
|
525
|
700
|
1,050
|
Output voltage
|
V
|
0 to Mains supply voltage
|
Max. output frequency
|
Hz
|
400 Hz
|
Power
supply
|
Rated input voltage and frequency
|
3-phase 480 to 690 V, 50/60 Hz
|
Allowable voltage fluctuation
|
10% to −15%
|
Weight
|
kg
|
320
|
590
|
860
|
On request
|
Note: Assembled in IP54 cabinet including main switch and main contactor or motor driven circuit breaker.
Dimensions
Inverter with Regenerative Active Front End
Voltage class
|
Inverter model
|
Dimensions in mm
|
|
H
|
W
|
D
|
Weight (kg)
|
400 V
|
SX-D4055-E1_
|
2,250
|
800
|
600
|
380
|
|
SX-D4075-E1_
|
400
|
SX-D4090-E1_
|
900
|
480
|
SX-D4110-E1_
|
500
|
SX-D4132-E1_
|
SX-D4160-E1_
|
1,300
|
700
|
SX-D4200-E1_
|
1,500
|
750
|
SX-D4220-E1_
|
830
|
SX-D4250-E1_
|
880
|
SX-D4315-E1_
|
1,900
|
1,040
|
SX-D4355-E1_
|
2,200
|
1,210
|
SX-D4400-E1_
|
SX-D4450-E1_
|
2,500
|
1,370
|
SX-D4560-E1_
|
3,000
|
1,600
|
SX-D4630-E1_
|
3,300
|
1,700
|
SX-D4800-E1_
|
4,500
|
2,250
|
SX-D4900-E1_
|
On request
|
690 V
|
SX-D6110-E1_
|
2,250
|
800
|
600
|
410
|
SX-D6132-E1_
|
430
|
SX-D6160-E1_
|
900
|
540
|
SX-D6250-E1_
|
1,800
|
870
|
SX-D6315-E1_
|
SX-D6355-E1_
|
910
|
SX-D6450-E1_
|
2,800
|
1,350
|
SX-D6560-E1_
|
1,390
|
SX-D6710-E1_
|
On request
|
SX-D61K0-E1_
|
SX-D61K1-E1_
|
DC Supply with Regenerative Active Front End
Voltage class
|
AFR model
|
Dimensions in mm
|
|
H
|
W
|
D
|
Weight (kg)
|
400 V
|
SX-D4115-E1AR
|
2,250
|
600
|
600
|
290
|
|
SX-D4165-E1AR
|
800
|
400
|
SX-D4250-E1AR
|
1,000
|
560
|
SX-D4330-E1AR
|
1,200
|
660
|
SX-D4500-E1AR
|
1,500
|
830
|
SX-D4660-E1AR
|
1,800
|
1,100
|
SX-D41K0-E1AR
|
2,700
|
1,600
|
690 V
|
SX-D6200-E1AR
|
2,250
|
800
|
600
|
320
|
SX-D6400-E1AR
|
1,200
|
590
|
SX-D6600-E1AR
|
1,700
|
860
|
SX-D6800-E1AR
|
On request
|
SX-D61K2-E1AR
|
Yazılım
CX-Drive
Tek bir yazılım aracı ile servoların ve invertörlerin yapılandırma, devreye alma ve bakım karmaşıklığını ve zamanını azaltın. CX-Drive, yeni Accurax G5 servo sistem ve MX2 invertörlerdeki özellikleri destekliyor.
CX-One
CX-One, kullanıcıların tek bir kuruluma ve lisans numarasına sahip olan yalnızca bir yazılım paketi kullanarak çok sayıda PLC, HMI ve hareket kontrol sistemi gibi cihazı ve ağı oluşturabilmelerini, yapılandırabilmelerini ve programlayabilmelerini sağlar. Bu, konfigürasyonların karmaşıklığını önemli ölçüde azaltır ve otomasyon sistemlerinin en az eğitim ile programlanıp konfigüre edilmesini sağlar.