Type
|
Standard Type
|
Model for Sensor Communications Unit
|
NPN output
|
E3NX-MA11
|
E3NX-MA6
|
E3NX-MA0
|
PNP output
|
E3NX-MA41
|
E3NX-MA8
|
Connecting method
|
Pre-wired
|
Wire-saving Connector
|
Connector for Sensor Communications Unit
|
Inputs/outputs
|
Outputs
|
2 outputs
|
−
|
External inputs
|
−
|
−
|
Light source (wavelength)
|
Red, 4-element LED (625 nm)
|
Response time
|
Super-high-speed mode (SHS)
|
Operate or reset: 100 μs
|
High-speed mode (HS)
|
Operate or reset: 450 μs
|
Standard mode (Stnd)
|
Operate or reset: 1 ms
|
Giga-power mode (GIGA)
|
Operate or reset: 16 ms
|
Sensitivity adjustment
|
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment
|
Maximum connectable Units
|
30
|
With E3NW-ECT: 30 units
With E3NW-CCL: 16 units
|
No. of Units for mutual interference prevention
|
9
|
Functions
|
Automatic power control (APC)
|
Always enabled.
|
Dynamic power control (DPC)
|
Provided
|
Timer
|
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms
|
Zero reset
|
Negative values can be displayed. (Threshold value is shifted.)
|
Resetting settings
|
Select from initial reset (factory defaults) or user reset (saved settings).
|
Eco mode
|
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
|
Bank switching
|
Select from banks 1 to 4.
|
Power tuning
|
Select from ON or OFF.
|
Output 1
|
Select from normal detection mode or area detection mode.
|
Output 2
|
Select from normal detection mode, AND output mode, OR output mode, XOR output mode,
GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode.
|
Hysteresis width
|
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
|
Ambient illumination (Receiver side)
|
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
|
Ambient temperature range
|
Operating:
Groups of 1 or 2 Amplifier Units: −25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage:
−30 to 70°C (with no icing or condensation)
|
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C,
Groups of 3 to 10 Amplifier Units: 0 to 50°C,
Groups of 11 to 16 Amplifier Units: 0 to 45°C,
Groups of 17 to 30 Amplifier Units: 0 to 40°C
Storage:
−30 to 70°C (with no icing or condensation)
|
Ambient humidity range
|
Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above
|
Insulation resistance
|
20 MΩ min. (at 500 VDC)
|
Vibration resistance (destruction)
|
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
|
Shock resistance (destruction)
|
500 m/s² for 3 times each in X, Y, and Z directions
|
150 m/s² for 3 times each in X, Y, and Z directions
|
Degree of protection
|
IEC 60529 IP50 (with Protective Cover attached)
|
Weight
(packed state/Sensor only)
|
Approx. 115 g/
approx. 75 g
|
Approx. 60g/
approx. 20g
|
Approx. 65 g/
approx. 25 g
|
Materials
|
Case
|
Polycarbonate (PC)
|
Cover
|
Polycarbonate (PC)
|
Cable
|
PVC
|